Slc 5 02 plc software

With most modern plcs, all you need to start programming or. How to configure the 1747pic to connect to a slc 500, slc 5. Specification slc 5 01 1747l511, l514 slc 5 02 1747l524 program memory 1k or 4k instructions 4k instructions additional data storage 0 0 maximum io capacity 3940 discrete inputs 3940 discrete outputs 4096 discrete inputs 4096 discrete outputs max. The slc 501, 502, and 503 use dh485 via their rs485 8pin rj45 jack. How to connect to an allenbradley slc 500 plc dmc, inc. Specification slc 501 1747l511, l514 slc 502 1747l524 program memory 1k or 4k instructions 4k instructions additional data storage 0 0 maximum io capacity 3940 discrete inputs 3940 discrete outputs 4096 discrete inputs 4096 discrete outputs max. The problem is when i tried to communicate with the plc with a pic 1747 and rslinx 2. Slc 502 for more complex applications, communications, faster scan times, and. Power it up and download the modified program from the slc 502. Jan 27, 2017 learn how to setup rslinx dh485 communications to an ab slc 500 and then download using rslogix in episode 17 of the automation minute season 3. In general, the slc500 programming software has a few less features than the plc5 programming software.

Communicate and download over dh485 using rslinx and rslogix 500. Before you begin, first insure your slc500 has serial port not all do. This software facilitates the machine design process, letting you quickly design and validate new machine concepts without purchasing or installing physical equipment. A total of 2 cables are required, 1747uic, plug into the usb port of the computer, and the ok indicator lights after connecting. Opc certification requires extensive testing to ensure true interoperability. But dont worry while the plc5 control system is discontinued and no longer available for sale, we have the tools and. Our slc 501, 502 and 503 8k series controllers are discontinued and no longer available for sale. Jan 20, 2011 configuring the ip address for an slc 5 05 controller can be accomplished in one of two ways, with a serial cable or the bootp server configuration utility in rslinx software version 2. Youll need a 1747uic the ebay knockoff adaptors work just fine. Allen bradley slc 500 plc configurator processor engnet.

Problems communicating with slc 500 501 allen bradley. Specifically, the slc503, slc504, and slc505 all have a 9 pin dshell serial port. Utilities for readingwriting data in a slc 505 over ethernet. Allen bradley plc connection procedure columbia machine. Local chassisslots 330 330 programming software rslogix 500, plc500 a. The allenbradley 1747l524 slc 502 is a popular modular processor. Next, insure you have the rslogix 500 programming software and either the 1747cp3 or equivalent null modem cable. Feb 01, 2008 i need to make program changes to a slc 502. Over time, you can then retrofit other parts of the system eg. The next slc500 controller to come out was the slc502.

Rslogix 500 to edit, upload and executing a ladder logic program using a micrologix 1500 plc duration. Panelmate and plc except the plc that you want to load the program. Dont bother with the 1747pic, it requires an older operating system to work correctly. Slc 503, slc 504, and slc 505 modular processors 11 publication 1747in009benp march 2008 3. Usb cables free delivery possible on eligible purchases. It allows fast slc 504toslc 504 communications and connectivity directly to plc5s. This ab software and hardware may control 5vdc, 24vdc, or 120vac circuits, high.

Kepserverex is more than an opc serverits a connectivity platform for industrial automation and iot. With a large number of legacy systems, the original programming cables and software are often long lost by the time you want to make updates or need to troubleshoot an issue. To access the slc 5 02 you will need the rockwell programing software rslogix 500, and rslinx to comunicate with it. How to configure the 1747pic to connect to a slc 500, slc 501, or slc 502 setting up a pic driver for allen bradley plcs this is used for slc 500, slc 501, slc 502, you will need a 1747pic cable or equivalent. How to connect to an allenbradley slc 500 plc plc one. It can also be used for most allen bradley products configured for dh485 including the slc 504, 505, controllogix, micrologix. On site there is a slc 5 02 plc 1996, with spare slots. Advanced interface programming software for the slc500, called plc500 a. A total of 2 cables are required, 1747uic, plug into. Hi, i have been asked to modify a machine as follows. This slc 502 processor has 4096 inputs, 4096 outputs, and 480 analog io. Contact your local sales office or distributor to discover how you can ease your migration to selected compactlogix controllers. You should only need the new slc 5 05 and a spare io rack.

Rslogix 500 downloading a new project to a controller slc 505. However, i cant agree with you, because at this jobsite, there is a third slc 501 and i have succesfully connected, uploaded, and downloaded software to that slc 501 using this. Slc 500 modular hardware style catalog numbers 1747l511, 1747l514, 1747l524, 1747l531, 1747l532, 1747l533, 1747l541, 1747l542, 1747l543. Buy 1747pic ab slc501, 5 02, 5 03 series plc programming cable rs232 to rs485. Slc 500 controllers allenbradley rockwell automation. The slc 501, 5 02, and 503 use dh485 via their rs485 8pin rj45 jack. Slc 501 and slc 502 modular processors catalog numbers 1747l511, 1747l514, and 1747l524 inside. The allenbradley 1747l524 is a slc 500 slc 502 processor.

Will rslinx auto config the port and then autodetect the processor. Slc 5 01, slc 5 02, slc 5 03, slc 5 04, and slc 5 05. Dear all,we are executing a project to aquire plant data through network. Pyramid integrator plc5250 in most cases, as much of the original io racksmodules, field wiring, communication networks, and. To connect it to a pcs serial port you need an allenbradley 1747pic unit. Also you will need some kind of device to hook up over the 485 port. Then take your new slc 5 05 and place it in a second io rack, a spare one on your desk somewhere. The allenbradley 1747l524 slc 5 02 is a popular modular processor. Like most good things, even the plc5 has come to an end. Our slc 5 01, 5 02 and 5 03 8k series controllers are discontinued and no longer available for sale.

Rockwell automation has announced that some slc 500 bulletin. Then take your new slc 505 and place it in a second io rack, a spare one on your desk somewhere. Specifically, the slc503, slc502, 501, fixed slc500 all have an rj45 dh485 port. One of the most popular series of plcs from the 1990s to mid2000s is the allenbradly slc 500 series. Mostly allen bradley plc use two softwares for plc programming.

Specification slc 501 1747l511, l514 slc 502 1747l524 program memory 1k or 4k instructions 4k instructions additional data storage 0 0 maximum io capacity 3940 discrete inputs 3940 discrete. Configuring the ip address for an slc 505 controller can be accomplished in one of two ways, with a serial cable or the bootp server configuration utility in rslinx software version 2. Alternatively, you can buy a newused slc503 5 04 or 5 05 to avoid of headache of trying to communicate with the 5 02. This project uses slc 502 plc for communication, the method is for reference only. Slc 504 programmable controllers automation networks.

Plc programming with rslogix 500 will get you up to speed fast. In the plant most of the plcs are simatic s7 300 and 400 and a few are rockwell plcs. Additionally, this processor has 4,000 instructions of user memory. Communicate and download over data highway plus using rslinx and. While the 501 could communicate over a dh485 network. For see page important user information 4 safety considerations 5 install 6 apply power to. For see page important user information 4 safety considerations 5 install 6 apply power to your processor 8 load your software 8 establish communications with the processor 8 troubleshoot the processor 9 specifications 10 battery handling. They both came with a dh485 programming port that accepted an rj45 style connector. Slc 5 01 and slc 5 02 modular processors catalog numbers 1747l511, 1747l514, and 1747l524 inside. Plc programming with rslogix 500 engineer and technician. The bootp utility is the less common of the two methods, but it is a convenient tool if the serial port or serial cable is not available. Windows programming software rslogix 500 programming software maximizes. Allen bradley 93012se2200 rsview 32 works 300 plc software rev 6.

Select driver from available driver types and press add new button note. Each slc 501 processor has a dh485 port for programming and. View online or download allen bradley slc 502 installation instructions manual. Allen bradley rslogix 500 plc programming ab plc software. Allen bradley 1747l524 module cpu processor slc 500 series c b216888 product details. Manufactured by rockwell automation, the slc 502 is a slightly less powerful model than the slc 503 and is intended. This project uses slc 5 02 plc for communication, the method is for reference only. Communicate and download over data highway plus using rslinx and rslogix article. However, i cant agree with you, because at this jobsite, there is a third slc 5 01 and i have succesfully connected, uploaded, and downloaded software to that slc 5 01 using this usb converter this 3rd plc was not locked with the s. On site there is a slc 502 plc 1996, with spare slots.

Allenbradley 1747l524 slc 5 02 processor 4k memory dh485 communication. Panelmate and plc except the plc that you want to load. Simply download kepserverex, and then select from kepwares library of more. Then when ready, power down the slc 5 02, swap the slc 5 02 with the new slc 5 05, and turn the power back on. How to configure the 1747pic to connect to a slc 500, slc. All parts new or reconditioned are covered by aotewell 12 month warranty. Slc 500 modular hardware style user manual rockwell automation. Local chassisslots 330 330 programming software rslogix 500, plc 500 a. What are the differences between slc 5 series plcs. Rslogix 500 downloading a new project to a controller slc 5. Insert a new battery into the battery retaining clips. Configuration using rslogix 500 programming software. You can get a cheaper 485232 converter designed to work with the slc family. In addition to the features of the slc 502, they have a second builtin.

Give information about dh, control net, devicenet and ethernet protocol. We are aquiring all the data on a central wincc server through ethernet from all the plcs. Apr 26, 2015 rslogix 500 to edit, upload and executing a ladder logic program using a micrologix 1500 plc duration. Why the allenbradley ab 1747pic always had trouble working in microsoft windows software. Opc certification is the process of ensuring that applications meet the standards specified by the opc foundation. But dont worry while the plc5 control system is discontinued and no longer available for sale, we have the tools and assistance to help you migrate to our controllogix control systems. Based on midsized plc processors, the advanced programming sets of the slc 5 02 give it an edge over its market. Slc 501, 502 or 503 processor with a 1747aic isolated link coupler. Btw, dont confuse the plc 515, 520, 540, etc with the slc 502, 503. Allen bradley plc interview questions and answers ab plc. Our bulletin 1747 slc 500 control platform is used for a wide variety of applications. Page 10 slc 501 and slc 502 modular processors communication receive receive or initiate dh485 slc 501 slc 502 1 a 1747pic is required when connecting to the dh485 channel for.

To support your transition, we recommend that you migrate to our compactlogix 5380 control platform. Learn how to setup rslinx dh485 communications to an ab slc500 and then download using rslogix in episode 17 of the automation minute season 3. The proprietary data network used by allen bradley plcs to communicate information to and from other plcs on the network or to and from host computers attached to the network. The driver uses the csp protocol, sometimes refered to as abethernet. The pannel view needs its own software also to program it. Plc cable for programming slc 500, 501, 502, and 503 plcs. Manufactured by rockwell automation, the slc 5 02 is a slightly less powerful model than the slc 5 03 and is intended for less intensive operations. Specifically, the slc 5 03, slc 5 04, and slc 5 05 all have a 9 pin dshell serial port. Buy 1747pic ab slc501, 502, 503 series plc programming cable rs232 to rs485. Power it up and download the modified program from the slc 5 02. Slc 502 processors let you configure modular controllers of up to 4096. Identifying slc 5 02 processor communication errors.

The first slc, known simply as an slc500, was an integrated platform containing the cpu, power supply, and io all in one package. Next, insure you have the rslogix 500 programming software, for which there is. The io configuration must be specified before downloading the initial project and going online. How to configure the 1747pic to connect to a slc 500, slc 501, or slc 502 setting up a pic driver for allen bradley plcs this is used for slc 500, slc 501, slc 502, you will need a 1747pic cable or. While the 501 could communicate over a dh485 network, it was only able to respond to messages sent it from either a pc or future slc500 controllers 502, 503, etc. To support your transition, we recommend that you migrate to our.

Plug the battery connector into the socket as shown above. The proprietary data network used by allen bradley plcs to communicate information to and from other plcs on the. Pyramid integrator plc 5 250 in most cases, as much of the original io racksmodules, field wiring, communication networks, and hmiscada as you want can be left intact. The 502 and 503 platforms had dh485 data highway communications. Motion analyzer software is a comprehensive motionapplication sizing tool used for analysis, optimization, selection and validation of your kinetix motion control system. Selecting a memory module for the slc 501 and slc 502. A driver is a software component that enables kepserverex to meet the connectivity. Allenbradley slc 501 installation instructions manual pdf. Open rslinx by selecting start programs rockwell software rslinx rslinx. Reproduction of the contents of this manual, in whole or in part, without written permission of rockwell automation, inc. Allenbradley 1747l524 is a slc 500 slc 502 processor.

826 98 204 609 1547 443 1016 327 854 1472 649 369 885 1535 705 868 1451 1326 1446 952 859 586 342 713 885 1534 460 845 538 323 1539 70 261 455 1093 1377 398 1243 1060 1401 484 207 1100 343